Domestic Sewage Treatment Equipment
Scope of Application
This domestic sewage treatment equipment is applicable to the treatment of domestic sewage in residential areas, restaurants, hotels, sanatoriums, schools, mines, factories, and also suitable for the treatment of similar industrial sewage.
Equipment Characteristics
- It can be buried underground.
- It is fully automatically controlled and does not require personnel management.
- There is no sludge backflow.
- It has simple operation and convenient maintenance.
- It has low noise and no peculiar smell.
- It has a long service life.
Model Specifications
The buried domestic sewage treatment equipment produced by our company has two major series, namely the WSZ-A modular series and the WSZ-F glass fiber reinforced plastic series. The treatment capacity ranges from 0.5 to 50 m³/H, with a total of more than 30 specifications.

【WSZ-A type modular】
1. Process description The design of WSZ-A type equipment is mainly aimed at the treatment of domestic sewage and similar industrial organic sewage. Its main treatment method is to use the current relatively mature biochemical treatment technology - contact oxidation method. The water quality parameters are designed according to the general domestic water quality, water inlet BOD 20Omg/l and water outlet BOD 20mg/l. There are a total of six parts: (1) initial sedimentation tank; (2) contact oxidation tank; (3) second sedimentation tank; (4) disinfection tank and disinfection device; (5) sludge tank; (6) fan room and fan; the following are discussed separately:
(1) Initial sedimentation tank: The equipment initial sedimentation tank is a vertical flow sedimentation tank. The rising flow rate of sewage in the sedimentation tank is 0.6-0.7 mm/sec. The precipitated sludge is lifted into the sludge tank with air. (Note: WSZ-A O.5-5m3/h does not have an initial sedimentation tank)
(2) Contact oxidation tank: After initial sedimentation, water flows to the contact tank for biochemical treatment. The contact tank is divided into three levels, with a total residence time of more than 1 hour. The contact oxidation time of the reinforced equipment can reach 6 hours, and the filler is a novel trapezoidal filler. Easy to conjunctiva and not blocked. The specific surface area of the filler is 160m2/m3, and the gas-water ratio of the contact tank is about 12:1. (Note WSZ-A 0.5-5T/h, the contact pool is the second stage)
(3) Second sedimentation tank: After biochemical sedimentation tank, the second sedimentation tank is two vertical flow sedimentation tanks, and they operate in parallel. The rising flow rate is O.3-0.4 mm/sec. The sludge discharge is lifted to the sludge pool using air. (Note WSZ-A0.5-5mT/h, the sludge flows into the sludge pool)
(4) Disinfection tank and disinfection device: The disinfection tank is according to the specification: the standard 'TJI4-74' is 30 minutes. If it is hospital sewage, the disinfection tank can increase the residence time to 1-1.5 hours. The disinfection method is adopted to dissolve solid chlorine tablets. The disinfection device can continuously change the dosage according to the amount of water effluent, so as to achieve the purpose of more water effluent and more medicine, less water effluent and less medicine. Other disinfection devices can be prepared separately. (Note: If used in industrial sewage disinfection tanks and disinfection devices, please do not)
(5) Sludge pool: All sludge in the primary sedimentation tank and the second sedimentation tank are lifted into the WSZ-A sludge pool for aerobic digestion. The clear liquid from the sludge pool is refluxed into the contact oxidation tank for reprocessing. There is very little sludge left after digestion, usually cleaned once every 1-2 years. The cleaning method can use a manure suction truck to extend from the inspection hole of the sludge pool into the bottom of the sludge for suction and transportation. (WSZ-A 0.5-5T/h, sludge is digested by anaerobicity)
(6) Fan room and fan: The fan room of the equipment WSZ-A is located above the disinfection pool, and the imported one uses double-layer sound insulation. The air inlet has a muffler and fan filter, so there is no noise during operation. The fan uses two L-shaped Roots blowers, which can automatically alternately. The operating life of a single fan is about 30,000 hours.
2. Technical parameters of WSZ-A equipment
Name | Type | A-0.5 | A-1 | A-3 | A-5 | A-10 | A-20 | A-30 |
Processing volume(m3/h) | 0.5 | 1 | 3 | 5 | 10 | 20 | 30 |
Fan | Type | L13LD | L13LD | L12LD | L12LD | L22LD | L23LD | L32LD |
power(kw) | 0.75 | 0.75 | 1.5 | 1.5 | 2.2 | 4 | 7.5 |
Water pump | Type | AS10-2CB | AS10-2CB | AS10-2CB | AS10-2CB | AS10-2CB | AS16-2CB | AS16-2CB |
power(kw) | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.6 | 1.6 |
Water inlet | BOD5mg/l | 200-400 |
Out of water | BOD5mg/l | 20-60 |
Equipment weight (t) approx. | 2.5 | 4.5 | 6 | 9 | 9 | 12 | 15 |
3. Relationship between WSZ-A equipment processing volume and water inlet and outlet BOD5
Water pump BOD5mg/L | 200 | 300 | 400 | 200 | 300 | 400 | 500 | 300 | 400 | 500 |
Water inlet BOD5mg/L | 20 | 20 | 20 | 30 | 30 | 30 | 30 | 60 | 60 | 60 |
Water treatment amount(m3/h) | A-0.5 | 0.5 | 0.4 | 0.33 | 0.5 | 0.4 | 0.38 | 0.3 | 0.5 | 0.43 | 0.38 |
A-1 | 1 | 0.8 | 0.65 | 1 | 0.9 | 0.75 | 0.6 | 1 | 0.85 | 0.75 |
A-3 | 3 | 2.4 | 1.95 | 3 | 2.7 | 2.55 | 1.8 | 3 | 2.55 | 2.55 |
A-5 | 5 | 4 | 3.25 | 5 | 4.5 | 3.75 | 3 | 5 | 4.25 | 3.75 |
A-10 | 10 | 8 | 6.5 | 10 | 9 | 7.5 | 6 | 40 | 8.5 | 7.5 |
A-20 | 20 | 16 | 13 | 20 | 18 | 15 | 12 | 20 | 17 | 15 |
A-30 | 30 | 24 | 19.5 | 30 | 27 | 22.5 | 18 | 30 | 25.5 | 22.5 |
【WSZ-F type modular】:
1. Overview This product provides users with a complete set of organic sewage treatment equipment that can be installed buried. The main purpose is to enable domestic sewage and industrial organic sewage similar to it to meet the emission standards required by users after being treated by the equipment. The WSH-F equipment, which combines a new process with fiberglass material as the main structure, has brought the sewage treatment process and manufacturing to a new level, thus making the sewage treatment equipment in this field reach an advanced level.
2. Technical Parameters Table 1 of WSZ-F Equipment
Water pump
Water pump | Water inlet |
|
BOD5 | 100-200 | 20 |
CODcr | 200-400 | 70 |
SS | 200-450 | 30 |
III. Technical Parameters Table 2 of WSZ-F Equipment
Project model | F-1 | F-3 | F-5 | F-7.5 | F-10 | F-15 | F-20 | F-30 | F-40 | F-50 |
Processing volume(m3/h) | 1 | 3 | 5 | 7.5 | 10 | 15 | 20 | 30 | 40 | 50 |
Number of equipment | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 3 | 4 | 4 |
Sludge adsorption and initial sedimentation tank(m3) | 1.8 | 5.5 | 9 | 14 | 18 | 27 | 36 | 50 | 80 | 100 |
Contact oxidation tank(m3) | 5.0 | 14.5 | 24 | 36 | 44 | 63 | 80 | 130 | 170 | 200 |
The surface load of the second sedimentation tank(m3/m2h) | 1.2 | 1.3 | 1.3 | 1.3 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.6 |
Disinfection pool(m3) | 0.6 | 1.8 | 2.8 | 4 | 5.5 | 8 | 10 | 15 | 20 | 25 |
Fan | model | HC-25IS | HC-30IS | HC-50C | HC-50IS | HC-60S | HC-80S | HC-100S | HC-100S | HC-100S | HC-100S |
power(kw) | 0.4 | 0.75 | 1.5 | 2.2 | 2.2 | 3.7 | 5.5 | 5.5 | 5.5X2 | 5.5X2 |
Number of units | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 |
Water pump | model | AS10-2CB | AS16-2CB | AS20-2CB |
power(kw) | 1.0 | 1.6 | 2.9 |
Maximum number of pieces(t) | 5 | 6 | 7 | 10 | 8 | 10 | 10.5 | 10.5 | 10.5 | 12 |
Total equipment weight(t) | 5.5 | 6.5 | 8 | 11 | 17 | 20 | 21 | 29 | 38 | 42 |
Area(m2) | 8 | 14 | 20 | 30 | 50 | 65 | 75 | 115 | 155 | 185 |